When it is found that there is solvent vapor leakage when the Organic solvent recovery equipment is working, the following problems may exist:

(1) The cooling pipe is blocked: the steam does not flow out after cooling through the cooling management, and a certain pressure is generated in the recovery barrel, and the steam overflows from the end of the recovery barrel under the pressure. The solution is the same as above.

(2) Poor sealing of sealing ring: the sealing ring of solvent recovery machine should be replaced every 3000 times. Solution: contact the manufacturer or supplier to replace the sealing ring.