RTO with flue gas treatment

Process Data:

Type: RTO for Air contaminated by Chlorinated Compounds - 2 canisters

with compensation chamber


Source of wastes: Wastewater treatment plant and Pharmaceutical

production plant


Capacity: 5000 Nm3/h


Hydrocarbons in Air: 2-5 g/Nm3

(Xylene, Toluene, Methylene Chloride,

Acetone, n-Heptane)


Guarantee: 

Outlet NOx concentration: < 150 mg/Nm3


Outlet TOC concetration: < 20 mg/Nm3


Plant sections: Final scrubber and Dry abatement


Solvent recovery