RTO with flue gas treatment
Process Data:
Type: RTO for Air contaminated by Chlorinated Compounds - 2 canisters
with compensation chamber
Source of wastes: Wastewater treatment plant and Pharmaceutical
production plant
Capacity: 5000 Nm3/h
Hydrocarbons in Air: 2-5 g/Nm3
(Xylene, Toluene, Methylene Chloride,
Acetone, n-Heptane)
Guarantee:
Outlet NOx concentration: < 150 mg/Nm3
Outlet TOC concetration: < 20 mg/Nm3
Plant sections: Final scrubber and Dry abatement